British Standard 8233:1999

When internal levels are considered, guidance on suitable internal noise levels can be found in BS 8233: 1999. BS 8233 provides guidance values for a range of ambient noise levels within residential properties as shown in the table below.

Internal Ambient Noise Levels for Bedrooms and Living Rooms

Citation Typical Situation Design Range dB LAeq,t
Good Reasonable
Reasonable resting/ sleeping conditions Living rooms 30 40
Bedrooms 30 35

BS8233:1999 states that "for a reasonable standard in bedrooms at night, individual noise events should normally not exceed 45dB". To equate this to an external noise level, BS8233 indicates that any type of window in a facade when partially open provides a weighted sound reduction index RW of 10-15 dB. This gives an external level of 55 to 60 dB LAmax,F.







Call us now for a free informal chat on 0845 37 000 89.

Or

Send us an Email: info@premiermeasurements.co.uk